Search
Search results
- Auto Mounting an Unpartitioned iSCSI LUN at System Startup
... client the filesystem has been created on the iSCSI LUN (entire disk), without creating a partition on iSCSI LUN, i.e creating the file system onto the whole LUN (entire disk), instead of ...
Article - needee - 6 May 2009 - 4:16pm - 0 comments - 0 attachments
- Migrating SLES to Software RAID1
... one storage box to the other with 8 paths for each LUN . The only result had been an unusable busybox prompt and the error ...
Article - jrecord - 4 Apr 2008 - 4:26pm - 10 comments - 0 attachments
- OES2 SP1 Install and Migration
... Why do we do this? We don't like to setup one big LUN (virtual disk, logical drive , whatever your RAID ... With OES2, you ALWAYS want to setup a dedicated LUN for your "boot" code, and leave a separate LUN for NSS (if using NSS). ...
Article - khurni - 6 Oct 2009 - 2:53pm - 3 comments - 1 attachment
- OES2 SP1 Migration Utility
... out LUNs. On a standalone server, we currently have one LUN for all volumes (NetWare). On the Cluster servers, each volume is a LUN. On the Xiotech SAN , one LUN should be made for each volume ...
Article - khurni - 6 Oct 2009 - 2:57pm - 0 comments - 1 attachment
- NetWare Physical to Virtual (P2V) Conversion Process With Free Tools
... This process has only been tested with single disk (or LUN in the case of a "disk" being made up of a mirrored pair of disks) ...
Article - gavo - 13 Oct 2009 - 2:33pm - 4 comments - 1 attachment
- Using NPIV for Storage Access with XEN Virtualization
... NPIV provides a way of assigning a fibre channel LUN directly to a XEN guest, without having it assigned to the host that ... as follows: npiv:fabricname-wwpn-wwnn-targetid-lun To obtain these values you'll need to do a little detective work. ...
Article - MarkCRobinson - 11 Aug 2009 - 2:24pm - 0 comments - 0 attachments
- Migrating from NetWare to OES2 SP1 Linux in XEN VM
... cfq > /sys/block/xvdb/queue/scheduler (our first LUN , xvda was non-NSS, so it didn’t matter). Good info! Thanks ...
Article - khurni - 10 Sep 2009 - 11:33am - 1 comment - 0 attachments
- Multipathing on SLES 10
... The machine is booting from a multipathed LUN from the SAN that contains a / boot partition and the System root /. Configure the LUN that should boot the machine in the HBAs bios. The particular steps ... down the node name of the remote fc Port and the LUN Number of the boot LUN, e.g.: 0x500604843978c00f 6 (this is the same ...
Article - tsaupe - 27 Mar 2009 - 3:07am - 0 comments - 1 attachment
- Clustering XEN with Heartbeat and Advanced HASI
... Your SAN devices should be visible by now (2 for each LUN ), in my case /dev/sda, sdb, sdc, sdd . Note: this will dynamically ... we have duplicates because we have double paths for each LUN : # ## Global settings: should be sufficient, change it on your own ...
Article - variia - 15 Jul 2009 - 3:46pm - 4 comments - 1 attachment
- Configuring Novell Clustering with ESX Server
... server(that I have found). The first way is to use RAW Lun mapping for each Virtual Machine(VM). The second way is to use VMWare virtual disks. Using Raw Lun Mapping is a bit limiting in the sense that VMWare only allows you to have ...
Article - blittrell - 14 Dec 2007 - 3:58pm - 0 comments - 0 attachments